Midnite Solar
MNPV Combiner Box
The
MNPV3 &MNPV6 combiner is rated for outdoor use.
The
use of touch safe din rail mount fuse holders and fuses allow operation
up to 600 Volts. The
MNPV6 combiner comes with two copper bus bars. One for circuit breakers
and one for fuses. The MNPV3
busbar is designed for circuit breakers only.
Applications:
PV combiner
up to six strings using MNPV breakers rated for 150VDC. 120 amps
total output
PV combining up to four strings using MNATM6, 10 or 15 touch safe
fuse holders rated for 600VDC
DC load center using MNPV breakers
Features:
All aluminum
powder coated housing that wont rust
Flip up cover that can stay in the open position during installation
PV Negative bus bar with 14 useable openings (10 #14-6 and
4#1/0-14)
Chassis ground bus bar with 14 useable openings (10 #14-6
and 4#1/0-14)
Standard din rail to mount up to 6 breakers or 4 fuse holders
Tin plated copper bus bar to combine breaker outputs (MNPV6
busbar may be split in two)
Dead front cover snaps into place after wiring is complete
for safety
Knock outs for PV in and PV out on bottom and sides
Top surface is available to bring conduit in from directly
above the enclosure
Note: The plastic dead front fits very tight. You must first remove
the lid in order to remove the dead front.
The installation
of a PV combiner is fairly straight forward.
Select the location
to install your combiner first. Some systems have the PV modules
located close to the inverters and or battery system. If this is
the case, you can elect to mount the MNPV inside and run each PV
string down to the MNPV inside the house. This is convenient for
trouble shooting and upgrading. For longer runs the combiner will
be mounted outdoors on the pole for pole mounted PV arrays or similar
mounting for rack mounted arrays. The combiner can be mounted in
the vertical position or slanted backwards to accommodate up to
a 3/12 roof pitch. All unused holes should be blocked using RTV
sealant or some similar goop in order to keep rain and bugs out
of the enclosure.
Note the warning
label on each side of the enclosure. Care must be taken to insure
that no water will get on terminal busbars when mounted less than
vertical. Removal of the labels are allowed if conditions are met.
It is very common for critters to enter through an unused mounting
hole and take up roost. They will eventually degrade the performance
of your system to say nothing of the yuk factor upon discovery of
their nest.
Click
here for more MNPV installation information in PDF format.
The
picture on the right shows an MNPV6 with a MidNite Solar DC-GFP
installed inside along with two combiner breakers. This is a novel
use of the DC-GFP in the combiner enclosure.
The use of din
rail mount breakers assures flexibility of installation.