Details
Accessories and Options*
Remote control: For convenient finger-tip operation, including the new one-knob™ programming.
AGS module: Automatically starts and stops your generator based on temperature or battery voltage.
Magnum MS2812 Inverter/Charger
Specifications |
MS2812 |
||
Inverter Specifications |
|||
Input battery voltage |
12.6 VDC |
||
Nominal AC output voltage |
120 VAC |
||
Output frequency and accuracy |
60 Hz ± 0.04% |
||
Total Harmonic Distortion (THD) |
< 5% |
||
1 msec surge current (amps AC) |
70 |
||
100 msec surge current (amps AC) |
40 |
||
5 sec surge power (real watts) |
3900 |
||
30 sec surge power (real watts) |
3800 |
||
5 min surge power (real watts) |
3200 |
||
30 min surge power (real watts) |
3000 |
||
Continuous power output at 25° C |
2800 VA |
||
Rated input battery current |
267 ADC |
||
Inverter efficiency |
88% |
||
Transfer time |
16 msecs |
||
Search Mode (with remote) |
.3 ADC |
||
No Load (120 VAC output with remote) |
2 ADC |
||
Waveform |
Pure Sine Wave |
||
Charger Specifications |
|||
Continuous output at 25° C |
125 ADC |
||
Charger efficiency |
85% |
||
Power factor |
0.98 |
||
Input current at rated output (AC amps) |
18 |
General Features and Capabilities
Transfer relay capability |
2 legs at 30 A for 120 V/30 A or 240 V/50 A service |
Five stage charging capability |
Bulk, Absorb, Float, Equalize, and Battery Saver™ |
Battery temperature compensation |
With available temp sensor (battery temp 0 – 50° C) |
Remote inverter on/off switch |
With available pigtail to connect to dry contact |
Internal cooling |
0 to 120 cfm variable speed drive using dual 92mm brushless DC fans |
Overcurrent protection |
Yes, with two overlapping circuits |
Overtemperature protection |
Yes on transformer, MOSFETS, and battery |
Conformal coating on PCB’s for corrosion protection |
Yes |
Powder coated chassis & top for corrosion protection |
Yes |
Stainless steel fasteners for corrosion protection |
Yes |
Dual AC branch rated output breakers |
Optional on the MS2012 - AC breakers in 15 or 20 amp ratings |
Environmental Specifications |
|
Operating temperature |
|
Nonoperating temperature |
|
Operating humidity |
0 to 95% RH non condensing |
Physical Specifications |
|
Dimensions (l x w x h) |
13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm) |
Mounting |
Shelf (top or bottom up) or bulkhead (vents up) |
Weight |
53 lb (24 kg) |
Max operating altitude |
15,000’ (4570 m) |